Number | Item | Technical Parameters | Remark |
1 | Rated voltage | 76.8V | |
2 | Rated Capacit | 400Ah | |
3 | Minimum capacity | 400Ah | |
4 | Total system energ | 30.72KWh | 0~98% |
5 | System Available Energy | 30.72KWh | |
6 | Energy Density | / | |
7 | voltage range | 60-87.6V | |
8 | Maximum pulse discharge current (30S) | 400A | The maximum allowable 10s peak discharge current (≥40% SOC, 25℃) |
9 | Maximum Continuous Discharge Current | 200A | |
10 | Maximum continuous charging current | 200A | |
11 | Maximum SOC Operating Window | 20%~100% | |
12 | Nominal cycle life | 2500 times | Condition: 100%DOD, 1C/1C: The capacity decay rate is not large at 20% |
13 | Operating temperature | Charge:0-50℃ Discharge:-20-55℃ | |
14 | Constant power or constant current charging maximum voltage | 87.6V | |
15 | Constant power or constant current discharge minimum voltage | 60V | |
16 | 1month, 25℃, 50%SOC self-discharge rate | ≤5%/month | |
17 | Insulation resistance value (MΩ) | ≥50 | Total positive/negative pair housing with system assembled |
18 | IP protection class | IP55 | |
19 | System composition | 24S2P |